SCHURTER – KMF Protection Class II: Compact Power Entry Module for Protection Class II Equipment
SCHURTER expands its wide range of power entry modules to include versions, without ground pin, for use in protection class II double-insulated applications. The KMF power entry module is already very popular for use in protection class I equipment, due to its high functionality in a compact package. The new protection class II version is perfectly suited for medical equipment used at home where the medical standard prescribes the use of protection class II design.
The new KMF class II version is according to IEC 60320-1, style C18. It is particularly well suited for use in medical equipment according to the IEC standard 60601-1-11, which outlines additional safety measures specific to medical equipment intended for use in the home. There is increasing demand for such equipment as populations around the world age and healthcare costs continue to rise. Protection class II equipment, in contrast to protection class I equipment, generally has no metal case. This category of equipment is called double insulated, and requires higher safety levels for energized components relative to exposed surfaces. The KMF class II power entry module provides double insulation between energized components and exposed parts. This reinforced insulation is tested with a voltage of 4000 VDC between the energized conductor (L) and the neutral conductor (N) relative to the mounting panel.
The KMF line switch is available with a 2-pole line switch and a 1- or 2-pole fuse holder. For medical applications an “extra-safe” fuse holder is available that can only be opened with the aid of a tool. The EMC filter is available in medical and low leakage, M5, versions. This integrated filter at the power input provides highly effective interference suppression, which results in optimized electromagnetic compatibility. Current ratings range from 1-10 A at 250 VAC. Connections is taking place with quick-connect terminals 4.8 x 0.8 mm.
The KMF class I and class II are ENEC, cURus and CCC approved. They are suited for use in equipment according to IEC 60950, IEC 60601-1, in addition to IEC 60601-1-11.
Technical Data:
– IEC C18 power-inlet connector with 2-pole switch, 2-pole fuse holder and a filter
– M5 medical filter
– Rated currents: 1, 2, 4, 6, 10A (ENEC / UL / CSA, CCC) at 40°C
– Snap-in mounting 1.0 – 2.5 mm
– Faston connectors 4.8 x 0.8 mm
– For totally insulated equipment according to IEC 61140
– Suited for medical equipment according to IEC 60601-1
– Especially well-suited for medical equipment intended for use in the home according to IEC 60601-1-11
Application:
– For totally insulated equipment according to IEC 61140
– Suited for medical equipment according to IEC 60601-1
– Especially well-suited for medical equipment intended for use in the home according to IEC 60601-1-11
Internet: